     PROPER USE 
    The proper use includes the monitoring and the acoustic indication when the water level is exceeded. In addition, a isolated output for connecting further indication devices is available.
    The overflow protector is suitable for all open water containers:
    - for household use, as e.g. in bath tubs
    - for industrial use, as e.g. in water tanks or
    - for camping, as e.g. in sinks

     DESCRIPTION OF THE PRODUCT 


    The level alarm anti overflow functions on piles and can be then used without danger. A water probe connects fixed re to limps of alarm. It is equipped with two metal contacts which make it possible to detect the level of any liquid and a cable of 150 cm length connection.
    The probe must be installed inside the container with the maximum height of level which the liquid must reach. If the liquid reaches this level, the liquid makes a bridge on the two metal contacts and alarm anti owerflow send immediately an alarm.
    The tension supply is guaranteed by three piles of the type AAA (included).


     CONTROLS 
    1- Overflow protector with battery compartment on the backside and adhesive area (Velcro strip)
    2- ON/OFF power switch
    3- Acoustic output for the audio signal
    4- 2.5 mm jack socket for switching contact
    5- Connecting cable for switching contact with 2.5 mm jack plug and open lead ends for relay output (isolated NO contact)

     INSERTING THE BATTERIES 
    INSERTING THE BATTERIES

     

    a) Open the battery compartment by unscrewing the back panel of the device
    b) Insert 3 batteries of the type AAA into the battery compartment and observe the correct polarity
    c) Close the battery compartment and fasten the screws
    d) The overflow protector is now ready for operation


     TECHNICAL DATA 
    Operating voltage ................................: 4.5 V DC (3 x type AAA)
    Current consumption ...........................: 0.3 micronsA (standby) / 70mA (alarm)
    Alarm sound level.................................: 97 dB  
    Cable length to water sensor...............: 150 cm
    Cable length for switching contact ......: 150 cm
    Switching contact ................................: isolated NO contact  
    Switching power ...................................: max. 24 V / 200 mA
    Dimensions of the housing ...................: 85 x 60 x 25 (mm)
    Weight incl. batteries............................: approx. 105 g
    Operating temperature.........................: between +5°C and +50°C